TECHNICAL SPECIFICATIONS

Market Post Tower has ensured proper adaptation of its original infrastructure to accommodate the specific needs of its telecommunications clientele. The building provides numerous options for standby power generation, rooftop space, and riser space for data, air conditioning and electrical needs. On-site amenities serving the property include a full-service cafeteria, a sundry store, a United States post office, retail banking, and a concierge service.  

Structure: Steel frame with concrete slabs and concrete fireproofing.
Façade: Aluminum window system and gold tinted windows.
Roof: Roof space is limited to mechanical structures. Racks and additional equipment can be located on the 16th floor Tower Data Center.
Floor Loading: 50 - 80 pounds per sq. ft. live load (can be reinforced at column lines).
Ceiling Heights: Slab to slab: 13 ft, to lowest beams: 9'-11"
Column Distance: 28 ft. x 28 to 32 ft.
Electrical Capacity: Typical power allocation is approximately 40 watts per sq. ft. expandable to 80 watts per sq. ft.  Each cabinet and 4' x 6' cage receives a 110 volt, 20 amp circuit. Main power is 480 volt, 3 phase. 
Elevators: Five passenger sevice elevator operate during regular business hours. Two secure passenger elevators operate during non-business hours. One frieght elevator with a 3,500-pound capacity. 
Fire Suppression: Existing wet system can be converted to a pre-action system. FM-200 system can be installed. Meet-Me Room is a zoned pre-action system.
Security: Manned, on-site security is present 24/7/365. Keycard system is in place for after-hours building entry and floor access. 
Risers: Riser space available for Telecommunication pathways from diverse entries. Fully master-planned riser system, providing diverse riser capacity for fiber, HVAC piping, electric and fuel riser needs. 
Parking: Underground gated parking area, not open to public access.
Delivery Area Loading: A loading area in the surface lot at the south side of the building is available to tenants for delivery of equipment. 
Operating Engineers: On-site operating engineers to support building systems and provide tenant service. 
Other Core Systems: On-site building engineers available for tenant service.
Primary Power:  Market Post Tower has 480 volt, 3-phase power delivered to the central power riser on each floor via a conduit riser system. Power allocated is based on the tenant's actual demonstrated loads. Typical power allocation is 80 watts per sq. ft.in suite 1070 and 1090 data centers.
Emergency Power:  The Landlord has one 2000 KW generator, a 900 KW generator and a 500 KW generator. Generator power is brought to the power riser on each floor through a conduit riser system. An additional 2000 KW generator will be added as demand increases.
Fuel Storage: Market Post Tower has existing fuel storage and containment and associated pumping for 24 hours of continuous generator use.
HVAC Cooling: The Landlord is installing a new, fully redundant, 1,500-ton condenser water system with tenant tap-ins pre-installed in one of the wet risers on each floor.

Contact Us :

Jacqueline Fitzpatrick
Sr. Director of Sales
Phone: 408-918-4309 ( direct)
Mobile: 408-396-6464 (mobile)
Email: jfitzpatrick@crgwest.com (email)
www.marketposttower.com
www.onewilshire.com
www.1275k.com

Contact us:
Jacqueline Fitzpatrick 408.918.4309
Leigh Taylor 408.918.4307

© 2000 Carrier Hotels, Inc.
116 Village Boulevard, Suite 200
Princeton, NJ 08540
Phone:(609) 243-7525

Empowering Users TO Make Wise Decisions In A Complex Market