MEET ME ROOM

The MMR (Meet Me Room) is a carrier-neutral connection point operated by CRG West. The MMR allows tenants to cross-connect with each other and outside companies so as to establish a presence at Market Post Tower for networking with other carriers. The purpose of the MMR is to facilitate interconnections between various telecommunications providers and users.

Two MMR's are located at Market Post Tower (on the 2nd and 3rd floors), providing an entrance point and distribution throughout the building. Additional infrastructured data center (Tower Data Center) space is located on the 16th floor; providing (plug-and-play) cabinet or cage space with roof access readily available for wireless applications.

Benefits

  • Faster time-to-market
  • Multiple carrier options at the Main Distribution Frame (MDF)
  • Maximum carrier options
  • On-site tenant support services
  • Efficient customer deployment
MMR Locations Market Post Tower, 55 South Market Street, San Jose, CA
MMR 1 - 2th floor - 4,530 usf
MMR 3 - 3rd floor - 2,732 usf
Managed Hosting 19” or 23” cabinet; Includes: 1 meg DIA and
24/7 managed service
IDC - 10th floor - 7,000 usf
IDC - 14th floor - 15,000 usf
Electrical Service MMRs have 480 volt, 400 amp service. 26,000 amps available through diverse feeds.
Multiple UPS systems
Multiple DC power supplies available
Emergency Power Emergency power for the MMRs consists of a 900KW, a 500 KW generator, and a 2MW generator
License Fees  It costs nothing to connect to our MDF or to interconnect to any carriers. Cabinets start at $600.00 a month. Managed service / 1meg / cabinet at $1,000 a month. IDC space quotes available.
Premises Delivery  Cages and cabinets will be delivered with horizontal pathway access to the MDF. One 110 volt, 20 amp service connection will be pre-wired to each cage and cabinet. Additional power can be obtained upon request.
Operating Hours  Access available 24 hours/day, seven days/week.
Security  Manned, on-site security 24/7/365. A keycard system is used for after-hours building entry and floor access. The MDF area is an 'Escort Access Only' space.
HVAC  30 tons of cooling capacity for MMR 1
60 tons for MMR 2
Liebert HVAC installed in all IDC/Hosting spaces
1,500 ton condenser loop
Fire Suppression  MMRs and Internet Data Center (IDC). Dry pipe, pre-action
Rooftop Access  Rooftop space is available for multi-directional and optical wireless transmitters / receivers.

Meet Me Room expansion / improvement details:

Contact Us :

Jacqueline Fitzpatrick
Sr. Director of Sales
Phone: 408-918-4309 ( direct)
Mobile: 408-396-6464 (mobile)
Email: jfitzpatrick@crgwest.com (email)
www.marketposttower.com
www.onewilshire.com
www.1275k.com